Ambrielle

New!! FLUKE 18B+ Digital Multimeter F18B+ LED Tester Voltmeter replace F18B

Description: Original FLUKE 18B+ Digital MultiMeter with FREE carrying bag Origin China Attention notice Our aim is to make you happy and satisfy in our store totally, providing the best product and best service. However, there still some problem happen. Items may be broken during the shipping way or item can not work or compatible with your items suitable. If such anything or any problem happened, please send a message to us by ebay or our email. Firstly and directly, before leaving any feedback or open any dispute. Please give us the opportunity to resolve the problem. We must guarantee you 100% satisfaction in our store. If you want buy much quantity or any other type item you like, please contact us by our email, or ebay message we can supply you, and give you much more discount, the super quality and service. Tks! 100% Brand New include battery. Feature: LED backlight (new) MIN/MAX Mode (new) Larger screen: 1.5 times of F18B's (new) Faster response time than F18B (new) Date Hold Function Both Auto range and Manual range Selectable Over range protection for all ranges Polarity Indication: Indicates negative polarity Overflow Indication Sleep Mode /Auto Power off / Low Battery Indication Continuity Test with Alert Diode Test Power Supply: 2 x AA 1.5V Battery General Specifications: Maximum Voltage between any Terminal and Earth Ground: 1000 V Display(LCD)......................................................4000 counts,updates 3/sec Battery Type.......................................................2 AA,NEDA 15A, IEC LR6 Battery life..........................................................500 hours minimum(50 hours in LED Test mode without load. The hours with load depends on the type of LED under test) Temperatuer Operating............................................................0 deg to 40 deg Storage...............................................................-30 deg to 60 deg Relative Humidity Operating Humidity...........................................Non-condensing≤90%at 10deg to 30deg;≤75% at 30deg to 40deg Operating Humidity,40MC Range....................≤80% at 10deg to 30deg;≤70% at 30deg to 40deg Altitude Operating............................................................2000m Storage...............................................................12.000m Temperature Coefficient...................................0.1×(specified accuracy)/deg(<18deg or > 28deg) Fuse protection for current inputs...................440 mA,1000 V Fast Fuse, Fluck specified part only. 11A,1000v Fast Fuse, Fluke specified part only. Size(H×W×L)......................................................183×91×49.5(mm) Weight.................................................................455g IP Rating.............................................................IP 40 Safety..................................................................IEC 61010-1, IEC61010-2-030 600V CAT Ⅲ,1000V CATⅡ,Pollution Degree 2 Electromagnetic Environment..........................IEC 61326-1:Portable E lectromagnetic Compatibility.........................Applies to use in Korea only Class A Equipment(Industrial Broadcasting and Communication Equipment) ACCURACY SPECIFICATION Accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]) AC and DC Voltage Function Range Resolution Accuracy 15B+ 17B+ 18B+ AC Volts (40Hz-500Hz)[1] 4.000V 40.00V 400.0V 1000V 0.001V 0.01V 0.1V 1V 1.0 % + 3 1.0 % + 3 1.0 % + 3 AC Millivolts 400.0mV 0.1mV 3.0 % + 3 3.0 % + 3 3.0 % + 3 DC Millivolts 400.0mV 0.1mV 1.0 % + 10 1.0 % + 10 1.0 % + 10 DC volts 4.000V 40.00V 400.0V 1000V 0.001V 0.01V 0.1V 1V 0.5 % + 3 0.5 % + 3 0.5 % + 3 [1]All ac, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. AC and DC current Function Range Resolution Accuracy 15B+ 17B+ 18B+ AC Current μA (40 Hz-400Hz) 400.0 μA 4000 μA 0.1 μA 1 μA 1.5 % + 3 1.5 % + 3 1.5 % + 3 AC current Ma (40Hz – 400Hz) 40.00 m 400.0 mA 0.01 mA 0.1 mA 1.5 % + 3 1.5 % + 3 1.5 % + 3 AC current A[1] (40Hz – 400Hz) 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3 1.5 % + 3 1.5 % + 3 DC current μA 400.0 μA 4000 μA 0.1 μA 1 μA 1.5 % + 3 1.5 % + 3 1.5 % + 3 DC current mA 40.00 mA 400.0 mA 0.01 mA 0.1 mA 1.5 % + 3 1.5 % + 3 1.5 % + 3 DC current A[1] 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3 1.5 % + 3 1.5 % + 3 [1] 10 A duty cycle < minutes on, 20 minutes off. Diode Test, Temperature, Resistance, Capacitance, Frequency, and Duty Cycle Function Range Resolution Accuracy 15B+ 17B+ 18B+ Diode Test[1] 2.000V 0.001V 10 % Temperature 50.0°C-400.0°C 0°C-50.0°C -55.0°C -0°C 0.1°C NA 2 % +1°C 2°C 9% +2°C NA Resistance (Ohms) 400.0Ω 4.000KΩ 40.00KΩ 400.0KΩ 4.000MΩ 40.00MΩ 0.1Ω 0.001KΩ 0.01KΩ 0.1KΩ 0.001MΩ 0.01MΩ 0.5%+3 0.5%+2 0.5%+2 0.5%+2 0.5%+2 1.5%+3 0.5%+3 0.5%+2 0.5%+2 0.5%+2 0.5%+2 1.5%+3 0.5%+3 0.5%+2 0.5%+2 0.5%+2 0.5%+2 1.5%+3 Capacitance[2] 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF 0.01 nF 0.1 nF 0.001μF 0.01μF 0.1μF 1μF 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 Frequency[3] (10Hz -100kHz) Hz 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz NA 0.1%+3 0.1%+3 Duty Cycle[2] 1% to 99% 0.1 % NA 1%typical[4] 1% typical[4] [1] Typically, open circuit test voltage is 2.0 V and short circuit is <0.6 mA [2] Specifications do not include errors due to test lead capacitance and capacitance floor(may be up to 1.5nF in the 40 nF range). [3] All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. In puts below 1 % of range are not specified. [4] Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90 %. LED Test and Continuity Threshold Function Lighting Range Measurement Range Resolution Accuracy LED VF Test[1] (LED Test Socket) 1.00 to 6.00 V NA NA NA LED VF Test[2] ( Test leads) 1.00 to 6.00V 1.00 to 6.00V 0.01V 10%[3] Continuity Threshold NA NA NA NA [1] Open circuit test voltage is±12V and short-circuit current is<±5mA(typical) [2] Open circuit test voltage is±12V and short-circuit current is<±3mA(typical) [3] VF Measurement with driving current under2.2±0.4 mA Input Characteristics Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio AC Volts 1000V[1] >10MΩ,60 dB at dc, 50Hz or 60Hz _ AC Millivolts 400mV >1MΩ,<100pF >80dB at dc, 50Hz or 60 Hz _ DC Volts 1000V[1] >10MΩ,<100pF >100dB at dc, 50Hz or 60 Hz >60dB at 50Hz or 60 Hz DC Millivolts 400mV >1MΩ,<100pF >80dB at ac, 50 Hz or Hz _ [1]106V Hz Max STANDARD ACCESSORIES 1. A Pair of Original Test leads 2. F18B+ meter 3. FREE black carrying bag! 4. Original User manual. 5. Batteries(not include) Please note: This meter is made by FLUKE in China. Everything is original FLUKE product except the carrying bag which is FREE to you. Note: This meter is made by FLUKE manufacturer in China. Now China Fluke manufacturers don't provide printed English user manual. Please click here to download English user manual: http://assets.fluke.com/manuals/151718__umeng0000.pdf ************************************************************************************************************************** Payment: Please use Paypal for the payment. Shipping: The item will be shipped out in 1~3 business days after payment cleared We’ll notify you the order status and shipping info, the time shipped, the tracking number and the tracking website once it’s been shipped. If you don’t receive the email from us (thru eBay), please check your spam folder. Please contact your local post office for missing or damaged package. We ship USPS, UPS or Fedex depending on the item. Feedback: Once we receive positive feedback from you we will do the same for you. We want to be sure you are 100% satisfied with your purchase. Please contact us if there are any questions or concerns about your purchase first. Return: We offer a 14 days money back guarantee. Please contact us through ebay email before returning any items. 1. We don’t provide return label. 2. Please make sure item and its packing in good condition, and can be sold in the future. There is no marks on the item, not alternated. Return items should include the original packaging and accessories. Otherwise, we feel sorry that we could not be able to return full payment. 3. Please put a paper in the package, on which your ID number, purchase date and reasons for return should be marked. 4. Buyers are responsible for the return shipping costs and 8% open box fee under any circumstances.

Price: 162.19 USD

Location: Baltimore, Maryland

End Time: 2024-11-20T08:04:41.000Z

Shipping Cost: 0 USD

Product Images

New!! FLUKE 18B+ Digital Multimeter F18B+ LED Tester Voltmeter replace F18BNew!! FLUKE 18B+ Digital Multimeter F18B+ LED Tester Voltmeter replace F18BNew!! FLUKE 18B+ Digital Multimeter F18B+ LED Tester Voltmeter replace F18BNew!! FLUKE 18B+ Digital Multimeter F18B+ LED Tester Voltmeter replace F18BNew!! FLUKE 18B+ Digital Multimeter F18B+ LED Tester Voltmeter replace F18BNew!! FLUKE 18B+ Digital Multimeter F18B+ LED Tester Voltmeter replace F18B

Item Specifics

Restocking Fee: No

Return shipping will be paid by: Seller

All returns accepted: Returns Accepted

Item must be returned within: 30 Days

Refund will be given as: Money Back

Brand: Fluke

Type: Multimeter

Model: 18B+

UPC: Does not apply

MPN: F18B+

Display: Digital

Recommended

Fluke Electrical Outlet Tester GFCI, ST120 Socket Tester, Voltage Ground Neutral
Fluke Electrical Outlet Tester GFCI, ST120 Socket Tester, Voltage Ground Neutral

$8.99

View Details
Fluke 323 True-rms Digital Display Clamp Meter Multimeter 400 Amp 600-Volt
Fluke 323 True-rms Digital Display Clamp Meter Multimeter 400 Amp 600-Volt

$100.00

View Details
Fluke 51 II Single Input Digital Thermometer with 60Hz, LCD Display, Type K Bead
Fluke 51 II Single Input Digital Thermometer with 60Hz, LCD Display, Type K Bead

$275.99

View Details
Fluke 302+ plus AC400A Clamp Tester AC/DC Volt Amp Multimeter Average 400A NEW
Fluke 302+ plus AC400A Clamp Tester AC/DC Volt Amp Multimeter Average 400A NEW

$69.90

View Details
Fluke T5-600 Voltage Continuity and Current Electrical Tester #648227
Fluke T5-600 Voltage Continuity and Current Electrical Tester #648227

$134.99

View Details
Brand New Fluke 902 FC HVAC True-RMS Clamp Meter
Brand New Fluke 902 FC HVAC True-RMS Clamp Meter

$299.99

View Details
Fluke 233 True RMS Remote Display Digital Multimeter Detachable Tester  VG Cond.
Fluke 233 True RMS Remote Display Digital Multimeter Detachable Tester VG Cond.

$200.00

View Details
Fluke T5-1000 1000 Volt Continuity Current Electrical Tester - Working
Fluke T5-1000 1000 Volt Continuity Current Electrical Tester - Working

$79.99

View Details
Multimeter Test Leads for Fluke Meter Electrical Alligator Clip Probes 1000V 20A
Multimeter Test Leads for Fluke Meter Electrical Alligator Clip Probes 1000V 20A

$6.90

View Details
FLUKE 101 Basic Digital Multi-meter Portable Meter ACDC Volt Tester Industrial
FLUKE 101 Basic Digital Multi-meter Portable Meter ACDC Volt Tester Industrial

$56.52

View Details